AZ 8306 P4.2 vs P4.3: Reference Temperature Is Not Sample Temperature
Separate the AZ 8306 reporting reference from its manually entered sample temperature before comparing conductivity readings or adjusting calibration.
16 hours ago


Pressure Calibration: Keep Rising and Falling Errors Separate
A pressure-calibration average can conceal a failed reading. Keep rising and falling errors separate, calculate the difference and preserve the evidence for review.
2 days ago


AZ 8901 Airflow Looks 60 Times Too Low? Check cms Before Adjusting the Fan
The AZ 8901 labels metric airflow as cms: cubic metres per second. Check the time base, area and report conversion before changing equipment settings.
Nov 13


AZ 86031 DO Salinity Compensation: Check P62 Before Recalibrating
Moving an AZ 86031 between fresh and saline water? Verify the manual DO salinity entry, preserve original readings and document the comparison before changing calibration.
Nov 11


pH ATC Is Not a 25°C Sample Conversion: Make Field and Lab Checks Comparable
Automatic temperature compensation does not, by itself, convert an unknown sample to its pH at 25°C. Record temperature and control the method before comparing field and laboratory results.
Nov 11


AZ 8852 T1−T2 Checks: Both Probes Must Use the Same Thermocouple Type
Before relying on an AZ 8852 temperature difference, verify both probe types, the shared selection, display modes and the individual readings.
Nov 10


Dragino Soil Moisture Correction: Validate the Range Around Your Irrigation Trigger
Check soil correction breakpoints, extrapolation and independent reference readings before relying on a moisture percentage for irrigation decisions.
Nov 9


Pressure Calibration Height Differences: Check Liquid Head Before Adjusting Zero
A liquid-filled test line can create a real pressure difference between instruments at different heights. Define reference levels and head correction before adjusting a gauge.
Nov 8


Same Conductivity, Different TDS? Check the Conversion Factor Before Recalibrating
Resolve conflicting TDS readings by comparing conductivity, temperature basis and conversion factors before changing calibration.
Nov 4


IR Thermometer Calibration: Check the Source Aperture Before Adjusting the Reading
A stable blackbody display and a centred laser dot do not prove a valid comparison. Check working distance, optical spot and usable source aperture before adjusting an IR thermometer.
Nov 3
Transmitter Adjustment: Save As-Found Results Before Trimming the Output
Preserve a transmitter’s as-found results before adjustment. Use a worked 4–20 mA example and work-order checklist to keep original evidence, interventions and final verification distinct.
Nov 2


How to Measure Oil Tank Temperature with a Transmitter
How to Measure Oil Tank Temperature with a Transmitter
Oct 29


How to Choose the Right Pressure Transmitter for Industrial Applications
How to Choose the Right Pressure Transmitter for Industrial Applications
Oct 5


Acrel Meter Commissioning CT Ratios Phase Mapping and Reading Checks for Accurate Readings
Acrel Meter Commissioning CT Ratios Phase Mapping and Reading Checks for Accurate Readings
Oct 2


Choosing an Industrial Gas Detector for Confined SpacesCovers oxygen, toxic gas and combustible-gas sensors, diffusion versus pumped sampling, bump tests and calibration requirements
A confined space can look harmless from the outside and still be deadly inside. A tank, vault, sump, sewer, vessel, or crawl space may contain too little oxygen, too much toxic gas, or a flammable atmosphere that can ignite with a single spark. That is why the gas detector is not just another item on the entry permit. It is one of the few tools that gives workers a direct warning before an invisible hazard becomes an emergency. Choosing the right industrial gas detector means
Sep 5


Flow Meter Accuracy Explained: What ±0.5% and ±1% Really Mean
Flow Meter Accuracy Explained: What ±0.5% and ±1% Really Mean
Aug 26
Why Paying More for a 4-Gas Detector Doesn't Always Mean Better Value
When it comes to personal gas detection, safety is non-negotiable. But that doesn't mean you need to spend over $1,000 to purchase a reliable 4-gas detector backed by local Australian support. For many contractors, maintenance teams, utilities, councils and industrial workplaces, the challenge is finding a detector that delivers the essential features required for safe operation without stretching the equipment budget. That's where the ProSense Portable Voice-Alert 4-Gas Dete
Jul 26


Understanding Pressure Units & Their Industrial Importance and Conversion Essentials
Pressure plays a crucial role in many industries, from manufacturing and automotive to scientific research and hydraulics. Yet, understanding pressure units and their correct application can be confusing. Different regions and sectors use various units, and accurate conversion between them is essential, especially when calibrating sensors or designing systems. This post breaks down the most common pressure units, explains their significance, and provides practical guidance on
Apr 12


The Importance of Regular Calibration for Accurate Measurements
The Importance of Regular Calibration for Accurate Measurements
Jan 23