Optical RPM Reading Doubled? Verify Pulses per Revolution Before Adjusting the Drive

Nov 3
4 min read

Updated: Nov 5

An optical tachometer reports about twice the expected shaft speed. The reading is stable, so it looks convincing-but stability does not prove that each detected pulse represents one revolution. Before changing a drive setting or reporting overspeed, check the relationship between optical pulses and mechanical rotation.


The useful question is: what passes through the detector’s field of view during one complete turn? A second effective reflective target can create another pulse. The instrument’s interpretation of those pulses determines the displayed RPM. Establish that relationship before treating a suspicious result as a machine diagnosis.


Original conceptual illustration comparing one and two optical events per revolution alongside a generic tachometer

Original conceptual illustration; not a specific product, optical specification, live measurement or customer installation.


Key takeaways


  • Confirm effective optical events per revolution.

  • Keep the original indication and assumptions visible.

  • Use approved isolated access for target inspection.


1. Plan access before checking the target


This is a measurement interpretation guide, not a procedure for working near unguarded rotating machinery. Target inspection, preparation and any tape changes require the plant’s approved isolation and access arrangements. Never attach tape to a moving component, reach through guarding or defeat an interlock to obtain a reading.


WorkSafe Victoria’s plant isolation guidance explains the need to control inadvertent activation and stored energy during inspection and maintenance. Have competent people establish the safe method for the specific plant and jurisdiction. If a protected observation position cannot be provided, stop and arrange a different measurement solution.


2. Separate the meter’s specification from the target setup


The pictured AZ 8008 Contact & Non-Contact Optical Tachometer provides both contact and optical measurement functions. It is shown with a contact attachment; the photograph is not an operating example of non-contact measurement.



AZ Instrument’s 8008 product specification gives a non-contact range of 10–99,999 RPM and a non-contact measuring distance of 5–30 cm. It specifies a red LED beam and reflective tape. Use the exact model’s instructions rather than assuming every optical tachometer is a laser instrument or has the same range.


Those specifications do not establish a configurable pulses-per-revolution setting. Do not assume one exists. Obtain the operating instructions for the supplied unit and identify its selected mode, units and any documented scaling before interpreting the result.


3. Understand the factor-of-two clue


For a simple pulse-counting interpretation, pulse frequency in hertz equals shaft speed in RPM multiplied by effective pulses per revolution, divided by 60. An instrument assuming one pulse per turn would display twice the shaft RPM if it consistently accepted two pulses on every turn.


Manufacturer TASI’s explanation of multiple reflective marks describes both proportional errors and unstable results when optical targets are inconsistent. Multiple marks are only meaningful when the instrument’s configuration or an explicitly documented calculation accounts for them. This general principle does not establish any additional feature of the AZ 8008.


An exact ratio is a clue, not proof. Do not divide a questionable reading by two simply because the answer then agrees with a nameplate. First establish the target geometry and meter interpretation, and distinguish the actual shaft being observed from any separate shaft used for comparison.


4. A hypothetical calculation


Consider a shaft independently established at 720 RPM in an approved test arrangement. One effective optical event per revolution gives 12 pulses per second: 720 divided by 60. Two consistently detected events give 24 pulses per second. A one-pulse-per-turn interpretation would convert that to 1,440 RPM.


The calculation explains how a repeatable doubling can arise without a real speed increase. It does not prove that a particular field reading has this cause. Keep the measured indication and any calculated result as separate entries, with the assumed pulse count stated.


Hypothetical 720 RPM shaft produces 12 pulses per second with one event per turn or 24 with two events, which a one-event interpretation reports as 1440 RPM

Original explanatory diagram. Numerical values are hypothetical where shown; follow the actual equipment documentation and approved application method.


5. Build a defensible verification record


  1. Identify the measurement point precisely: asset, shaft or coupling, operating condition and why the expected speed is credible. Record whether the comparator is measured speed, a command value or an estimate.

  2. Record the tachometer model, selected mode and units. Preserve the initial reading, including fluctuations, instead of replacing it with an assumed correction.

  3. During approved isolated access, document the optical target and its surrounding surface. Establish how many effective events the intended observation path could produce per revolution.

  4. Check the documented operating distance, aiming requirements and target condition. Arrange any repeat measurement through the approved protected position, with the machine returned to its authorised operating condition.

  5. Compare against an independent suitable reference where the discrepancy matters. Retain the test conditions, acceptance criteria, result and unresolved limitations.


6. Avoid adjustments that conceal the uncertainty


Do not change motor parameters to make an unverified handheld reading match an expectation. Do not enter an undocumented correction into a maintenance spreadsheet and discard the original value. A held display should also be identified as a held result rather than presented as a new observation.


If the pulse relationship remains uncertain, report the RPM as unverified and request application support. Provide the exact instrument model, mode, initial readings, target photographs taken under safe access conditions, intended working distance and comparison evidence. This gives the reviewer enough information to choose a repeatable method without turning a display anomaly into an unsupported equipment fault.


Need help with your application?


For instruments and product selection, visit ProSense Instruments, email sales@prosenseinstruments.com.au or call 1800 560 854.


For monitoring and automation projects, visit ProSense Solutions or email sales@prosense.com.au.


For software enquiries, visit ProSight Software or email info@prosightsoftware.com. Confirm integration requirements for the exact instruments and system.