LoRaWAN Downlinks: Prove a Queued Setting Reached the Sensor
A queued LoRaWAN command is only one stage of a configuration change. Check Class A receive opportunities, scheduling events and device-side evidence before handover.
1 day ago


LHT65N Shows 327.67°C? Preserve the Disconnected-Probe Fault
Diagnose an LHT65N external-probe fault value without turning missing measurements into misleading temperatures, averages or alarm states.
6 days ago


LHT65N Outage Recovery: Keep Historical Readings Out of Live Alarm Rules
Recovered LHT65N readings can arrive late. Preserve observation and receipt times, classify historical records and test live alarm handling before deployment.
Nov 15


LHT65N Battery Reads 52 V? Separate Status Bits from Millivolts
A packed battery word can become a false 52 V reading. Verify the LHT65N message layout, separate status bits from millivolts and check downstream conversions.
Nov 13


LDDS75 Shows 20 mm? Reject Invalid Distance Before Calculating Tank Level
A received LDDS75 packet can contain an invalid distance. Check the firmware-specific 20 mm code before converting it into a misleading full-tank percentage.
Nov 10


Dragino RS485-LN MBFUN Not Taking Effect? Check DATACUT Priority
Check why an existing DATACUT extraction rule can override MBFUN on a Dragino RS485-LN, and validate the change using serial responses and uplinks.
Nov 6


Modbus Address Zero: Check the Destination Before Treating Silence as a Fault
Modbus serial address zero is reserved for broadcast exchanges. Check the transmitted destination before changing timeouts, wiring or converter settings.
Nov 5


Relocating a LoRaWAN Sensor: Separate Old and New ADR Test Evidence
Build a defensible radio acceptance record after moving a LoRaWAN sensor, separating bench results, ADR observations and final-position delivery evidence.
Nov 4
LoRaWAN Frame Counter Resets: Investigate Missing Data Without Weakening Replay Protection
Trace missing LoRaWAN readings after a restart by checking activation mode, frame counters and session evidence. Includes a hypothetical ABP example and recovery checklist.
Nov 1
Dragino PS-LB-NA Pulse Counts: Verify Restart Persistence and Reporting Mode
Counting mode and restart persistence are separate settings. Build a controlled acceptance test that checks the raw count and its interpretation after maintenance.
Oct 30
Dragino Payload Decoder Changes: A Validation Checklist Before Dashboard Rollout
Validate a Dragino decoder against the exact model, firmware, message port and engineering units before rolling it out to operational dashboards.
Oct 28


How to Calculate Battery Life for Dragino Sensors Using ER26500 and SPC1520
Compare Dragino LoRaWAN and Monnit platform requirements Browse Dragino sensors and equipment Plan a Dragino LoRaWAN kit That is why battery life needs a calculation, not a guess. This guide explains how the ER26500 + SPC1520 pack works, how to estimate run time, when to replace the pack, and why transmission interval matters so much for LoRaWAN and NB-IoT sensors. The ER26500 and SPC1520 pack is built for long-running outdoor sensor deployments. What the ER26500 and SPC1520
Oct 26


How to Maximize LoRaWAN Range with TX Power, DR, and ADR Settings
How to Maximize LoRaWAN Range with TX Power, DR, and ADR Settings
Oct 15


Dragino Pulse Counting for Rain Gauges and Production Counters: Choosing the Right Input Device
Dragino Pulse Counting for Rain Gauges and Production Counters: Choosing the Right Input Device
Oct 7


Wireless Monitoring for Existing Industrial Sensors with LoRaWAN and 4G Connectivity
Wireless Monitoring for Existing Industrial Sensors with LoRaWAN and 4G Connectivity
Sep 2


Monnit vs Dragino Which Wireless Sensor System Fits Your Needs Best
Monnit vs Dragino Which Wireless Sensor System Fits Your Needs Best
Aug 24


How Dragino LoRaWAN Sensors Power Remote Monitoring Systems
How Dragino LoRaWAN Sensors Power Remote Monitoring Systems
Aug 16