Supplier quality for major industrial projects

ProSense Pty Ltd supplies Australian asset owners, system integrators and Tier 1 contractors through ProSense Instruments and ProSense Solutions. A buyer can submit a single replacement part, a switchboard schedule or a multi-site equipment list. Tell us which records your purchaser or engineering team needs to accept delivery.

How we use ISO 9001 in purchasing

ProSense Pty Ltd uses ISO 9001 quality-management principles in purchasing and supplier review. When a project specifies ISO 9001, we ask which organisation and activity must be covered. We match the factory’s legal name, manufacturing scope and certificate dates to the quoted assembly. The purchasing record can also identify the full order code, any agreed substitution, the required inspection and the documents to accompany delivery.

Custom temperature probes and factory certification

ProSense holds selected stock in Australia and commissions custom assemblies through manufacturing partners. For assemblies supplied through Senster, Taizhou Chuangmei Instrument Technology Co., Ltd. holds ISO 9001:2015 certification for thermocouple and thermal-resistance manufacture. The factory certificate applies to the activities and site identified in the document.

View the probe manufacturer’s ISO 9001:2015 certificate

Specify a custom RTD, thermocouple or thermistor

Australian electrical compliance and hazardous-area equipment

ProSense Pty Ltd, ABN 55 680 423 956, is a registered Responsible Supplier on the Electrical Equipment Safety System. For equipment subject to Australian electrical safety or ACMA requirements, quote the exact variant and request the applicable Regulatory Compliance Mark (RCM) evidence. For a hazardous-area application, include your required certification scheme and the equipment marking from the specification. We can then check the certificate schedule for the model and options on offer.

Check the EESS Responsible Supplier register

Teltonika publishes two Australian supplier declarations for RUT951 and RUT956 LTE routers. Both identify the models and required RCM marking. The compliance folders are P22666LR and P22667LR. Give us the full router order code and any supplied power adaptor so we can check the applicable configuration and documents.

Check the IECEx equipment certification scheme

Find certificates by manufacturer

Look up the manufacturer and the exact model to see the scope of its factory certificate, electrical declaration, calibration evidence or Australian appointment. Browse supplier certificates and declarations

Automation, communications and machine safety — Coolmay · DEGSON · Dragino · Monnit · Milesight · Teltonika Networks · Bivocom · NOAKWELL · Kernal Automation

Process measurement and recording — Madincos · GTI / GTIMEASURE · JUJEA · LEFOO · RIKA Sensor · Holykell · Huadian Automation · Senster · Sensirion components

Cold-chain loggers and portable measurement — FRESVUE · Tzone Digital · AZ Instrument · Gain Express · Shangyouji Industrial Technology

Electrical, power and optical test — Acrel · INOMAX · MEAN WELL · VLUUKE · RIGOL · KomShine · Yueqing Xianglang Electric

Manufacturer documents by product

JUJEA’s supplied Chinese explosion-protection certificate ZJEx25.1156 identifies its JJTMF thermal gas mass flow meter under GB/T 3836.1-2021 and GB/T 3836.2-2021. For an IECEx or ATEX specification, request the corresponding scheme certificate and exact model schedule.

View the JUJEA JJTMF certificate and model marking

See JUJEA’s four factory inspection stages

NOAKWELL’s electromagnetic compatibility certificate LH-240801013388 names NK-40, NK-20, NK-10, FK-40, FK-20, PR-25 and PR-45 safety grating sensors. Issued on 8 August 2024, it covers the listed samples against the EU EMC Directive. For a machine-safety assessment, request separate functional-safety evidence for the exact transmitter, receiver and controller.

Download the NOAKWELL EMC certificate (PDF)

Xiamen Madincos Automation supplies model-specific records for industrial measurement equipment. The MPR5000ST paperless recorder has an EMC record, the MPD580 process indicator has a low-voltage record and the MVT100 vibration transmitter has an EMC record. Check the model and options shown on each document.

Madincos MPR5000ST recorder EMC declaration (PDF)

Madincos MPD580 indicator low-voltage declaration (PDF)

Madincos MVT100 vibration transmitter EMC certificate (PDF)

Standards by project and application

Include the required standard, edition and acceptance document beside the relevant line of your equipment schedule. That lets us distinguish a factory certificate from an individual calibration result, a component safety manual or a system validation record.

NATA-endorsed calibration and NIST traceability

ProSense works with independent NATA-accredited calibration laboratories in Australia. For eligible instruments, the laboratory issues an endorsed report for measurements within its accredited scope. Specify the quantity, range, points and uncertainty so the laboratory can confirm its accredited scope. For NIST-traceable measurements, identify the model or serial number and request the documented chain of calibrations. Monnit’s detachable temperature leads are one manufacturer example.

Specify calibration and report requirements

View Monnit’s detachable lead and traceability information

Functional safety and SIL

For a safety instrumented function, specify the target Safety Integrity Level (SIL), intended function, component and revision. Procurement can then obtain the safety manual, applicable certificate and conditions of use. For example, Siemens documents SIL 3 configurations for its SIMATIC F-DI 16×24 V DC input module, order number 6ES7526-1BH00-0AB0. The system integrator validates the complete safety function.

Siemens fail-safe input module equipment manual (PDF)

HACCP monitoring and EN 12830 temperature recorders

For a food safety plan, we supply probes, data loggers and alarms for monitoring critical limits. Send the critical control point, product temperature limit, recording interval and corrective-action record you need. Where a purchaser specifies EN 12830 for transport, storage or distribution of temperature-sensitive goods, request the manufacturer’s evidence for the exact recorder and probe configuration.

Food safety programmes and HACCP

EN 12830 temperature recorder scope

FDA 21 CFR Part 11 electronic records

For regulated electronic records and signatures, identify the records relied on, software version, user roles, audit-trail and signature requirements, retention period and validation responsibilities. ProSense can scope the hardware, software and documentation against that brief. Site procedures and validation form part of the implemented system.

FDA guidance on electronic records and electronic signatures

EN 280-1 for mobile elevating work platforms

For access-platform projects, include the machine model and the EN 280-1 clause in the enquiry. A component supplier can provide evidence for the specified component. The machine manufacturer or responsible assessor addresses conformity of the assembled platform.

EN 280-1 mobile elevating work platform scope

About ProSense Group and the operating company

Manufacturer relationships and warranty

LEFOO appoints ProSense as its Australian representative for transmitters and switches and extends its manufacturer warranty to covered goods. FRESVUE authorises ProSense to distribute its cold-chain loggers and provide Australian technical and commercial support. Monnit lists ProSense in its Australian partner directory.

The catalogue also covers RIKA environmental sensors, Coolmay automation, Dragino wireless devices, VLUUKE electrical test equipment and DEGSON connectors. For major-brand equipment, the quotation can specify the supply route, condition, warranty provider and term. Ask for serial or lot records and conformity documentation at enquiry stage.

View Monnit’s partner directory

Explore FRESVUE wholesale, OEM and deployment options

For major-project schedules, ProSense can also quote specified Siemens, Schneider Electric and ABB parts by full order code. Our quotation can identify the supply channel, local or supplier availability and warranty for each line.

Source an international brand by part number

Request accredited calibration for a specified range

Identify the equipment and its intended use

Include the manufacturer, full model and option codes, destination and any project specification. State which declarations, test reports, drawings or certificates your purchaser needs before accepting the equipment.

Match evidence to the supplied configuration

Ask for the issuing organisation, document revision and the models or serial numbers covered. For a multi-line order, identify each requested record against its PO line so your team can assemble a traceable submission.

Calibration and service records

For a calibration quotation, include the serial number, measurement range, requested points and any accredited-scope requirement. Technical sales can confirm the provider and documentation for that instrument.

Calibration and certificate requests

Browse the technical resource centre

Submit a project documentation request

bottom of page