top of page
SKU: G-30x30i

ACREL AKH-0.66 G-30x30i Low Voltage Current Transformer

From AU$71.00Sale Price
Excluding Sales Tax
Variant
G-30x30i | 5/5 | 0.2
G-30x30i | 10/5 | 0.2
G-30x30i | 15/5 | 0.2
G-30x30i | 20-25/5 | 0.2
G-30x30i | 30/5 | 0.2
G-30x30i | 40-75/5 | 0.2
G-30x30i | 100-150/5 | 0.2
G-30x30i | 200/5 | 0.2
G-30x30i | 250-400/5 | 0.2
G-30x30i | 5/5 | 0.5S
G-30x30i | 10/5 | 0.5S
G-30x30i | 15/5 | 0.5S
G-30x30i | 20-25/5 | 0.5S
G-30x30i | 30/5 | 0.5S
G-30x30i | 40-75/5 | 0.5S
G-30x30i | 100-150/5 | 0.5S
G-30x30i | 200/5 | 0.5S
G-30x30i | 250-400/5 | 0.5S
G-30x30i | 5/5 | 0.2S
G-30x30i | 10/5 | 0.2S
G-30x30i | 15/5 | 0.2S
G-30x30i | 20-25/5 | 0.2S
G-30x30i | 30/5 | 0.2S
G-30x30i | 40-75/5 | 0.2S
G-30x30i | 100-150/5 | 0.2S
G-30x30i | 200/5 | 0.2S
G-30x30i | 250-400/5 | 0.2S
Quantity

ACREL AKH-0.66 G-30x30i Low Voltage Current Transformer is a low voltage current transformer that steps a primary current down to a 5A secondary signal for meters and monitoring equipment. It has a square window that takes either a cable or a busbar, and a clear cover so the secondary wiring can be checked at a glance.

         

        The ACREL AKH-0.66 G-30x30i Low Voltage Current Transformer is a compact current transformer for measuring alternating current in low voltage installations. It sits around a conductor and produces a smaller, proportional 5A signal that energy meters, power analysers and other instruments can read safely.

        It is a solid core design, so it is fitted during panel build or when a conductor is being installed, rather than clamped on afterwards. The window is sized for a 28 mm cable or a 30 x 10 mm busbar, and the housing has a transparent polycarbonate flip cover over the secondary terminals.

        How it works

        • The conductor being measured passes through the window and acts as the primary winding.
        • The transformer produces a proportional secondary current, 5A at the rated primary current.
        • Lower ratios are achieved by looping the conductor through the window several times. For example, the datasheet lists 16 turns for the 5/5 ratio and 1 turn for 100/5 and above.
        • The secondary output connects to a meter, transducer or monitoring device.

        Why choose this product

        • A wide ratio range in one housing, so the same body suits small feeders and large incomers.
        • Rated load and accuracy options are published for each ratio, which makes matching to a meter straightforward.
        • The clear cover allows a visual check of the secondary wiring without removing anything.
        • It is made by an established manufacturer with a published datasheet and defined test standards.

        Benefits

        • Fewer part numbers to stock when a project uses several current ratings.
        • Cable or busbar installation with the one unit.
        • Easier commissioning and inspection.

         

        4dfa305f-144b-447f-8853-f686658e8e2e.png
        bottom of page